12 Non maintained and maintained LED emergency lighting units Certified to IEC and EN 60598-2-22 standards related to luminaires for emergency lighting. High power LEDs with optimized lighting distribution (LED lifetime > 100,000 h) IP 42, IK 04 - Class II Power supply: 230 V ± 10% - 50/60 Hz. Switching power supply on maintained units. Duration: 1, 2 and 3 hours. Ni-Cd or Ni-MH batteries. Charging time: 24 hours. Charge monitor with a green LED Automatic terminals with high capacity: 2 x 2.5 mm² for the electrical power supply and for the remote control circuit Remote control terminals protected against reversed wiring with the power supply. The remote control may be used to remotely disable the emergency lighting units to avoid unnecessary battery discharge in the event of a deliberate cut in normal lighting. Opal diffuser 4 cable knock-outs for flexible sheath or rigid tube Ø20 mm : 1 entry in the base ; 2 entries in the sides ; 1 entry on the top Surface-mounting or flush-mounting with frame Cat. No 6 617 20 Indoor self-contained emergency lighting luminaire LED - U21 LED Indoor self-contained emergency lighting luminaire LED - U21 LED n Installation Surface-mounting 6 616 02 6 616 07 n Accessories Flush-mounting frame Flush-mounting cut-out in dry partitions with Cat. No 6 617 20 Flush-mounting cut-out in masonry with Cat. Nos 6 617 20 + 0 617 21 n Dimensions (in mm) 244 57,1 109 291.4 150.4 57.5 150.4 270 120 400 150 Pack Cat. Nos U21 LED Standard emergency lighting luminaires Standard luminaires require manual switching off of normal lighting in order to test emergency lighting Non maintained (NM) Lumens Duration Lamps Battery 10 6 616 01 70 1 h 2 LED Ni-Cd 10 6 616 02 100 1 h 2 LED Ni-Cd 10 6 616 05 160 1 h 4 LED Ni-Cd Maintained / Non maintained (M/NM) These Maintained luminaires can also operate in Non maintained mode according to the wiring of normal lighting Lumens Duration Lamps Battery 10 6 616 03 100 1 h 4 LED Ni-Cd 10 6 616 06 200 1 h 4 LED Ni-Cd 10 6 616 07 350 1 h 4 LED Ni-Cd 1 6 616 10 100 3 h 4 LED Ni-Cd 1 6 616 12 200 2 h 4 LED Ni-MH U21 LED Autotest / addressable LVS2 emergency lighting luminaires Maintained / Non maintained (M/NM) Autotest / addressable luminaires incorporate an automatic self-testing system in order to check the emergency mode The test’s result is visible on 2 signalling LEDs (green- OK and yellow-defective). Addressable function is activated by setting an ID on each luminaire with infrared configuration tool (Cat.No 0 626 10) and wiring a complementary BUS line. Operating status of all addressable luminaires can be centralized by the control interface (Cat.No 0 626 00) and monitored on a local touch screen controller (Cat.No 0 626 01), or with the building’s plan on Legrand Vision System (LVS2) PC software (Cat.No 0 626 02). These Maintained luminaires can also operate in Non maintained mode according to the wiring of normal lighting Lumens Duration Lamps Battery 1 6 626 03 100 1 h 4 LED Ni-Cd 1 6 626 06 200 1 h 4 LED Ni-Cd 1 6 626 07 350 1 h 4 LED Ni-MH 1 6 626 10 100 3 h 4 LED Ni-MH 1 6 626 12 200 2 h 4 LED Ni-MH Accessories Wall flush-mounting With frame and box 10 6 617 20 Flush-mounting frame for dry partition 10 0 617 21 Flush-mounting box for masonry Ceiling flush-mounting 10 6 617 20 Flush-mounting frame for dry partition

RkJQdWJsaXNoZXIy Mzk3OTY=