Legrand katalog

13 www.legrand. XX NEw LED EMERGENCY LIGHTING UNITS Maintained LED emergency lighting units which can also operate in Non maintained mode Certified to IEC and EN 60598-2-22 standards related to luminaires for emergency lighting High power LEDs with optimized lighting distribution (LED lifetime > 100,000 h) IP 65, IK 07- Class II Power supply: 230 V ± 10% - 50/60 Hz. Low consumption switching power supply Duration: 1 and 3 hours Ni-Cd or Ni-MH batteries. Charging time: 24 hours Charge monitor with a green LED Automatic terminals with high capacity: 2 x 2.5 mm² for the electrical power supply and for the remote control circuit Remote control terminals protected against reversed wiring with the power supply. The remote control may be used to remotely disable the emergency lighting units to avoid unnecessary battery discharge in the event of a deliberate cut in normal lighting Opal diffuser 3 flexible cable entries for rigid tube Ø16, 20 and 25 mm - 2 entries in the sides - 1 entry on the top Surface-mounting Pack Cat. Nos B65 LED Standard emergency lighting luminaires Maintained / Non maintained (M/NM) Standard luminaires require manual switching off of normal lighting in order to test emergency lighting These Maintained luminaires can also operate in Non maintained mode according to the wiring of normal lighting Lumens Duration Lamps Battery 1 6 614 31 100 1 h 4 LED Ni-Cd 1 6 614 33 200 1 h 4 LED Ni-Cd 1 6 614 34 350 1 h 4 LED Ni-Cd 1 6 614 40 100 3 h 4 LED Ni-Cd B65 LED Autotest / addressable LVS2 emergency lighting luminaires Maintained / Non maintained (M/NM) Autotest / addressable luminaires incorporate an automatic self-testing system in order to check the emergency mode The test’s result is visible on 2 signalling LEDs (green- OK and yellow-defective) Addressable function is activated by setting an ID on each luminaire with infrared configuration tool (Cat.No 0 626 10) and wiring a complementary BUS line. Operating status of all addressable luminaires can be centralized by the control interface (Cat.No 0 626 00) and monitored on a local touch screen controller (Cat.No 0 626 01), or with the building’s plan on Legrand Vision System (LVS2) PC software (Cat.No 0 626 02) These Maintained luminaires can also operate in Non maintained mode according to the wiring of normal lighting Lumens Duration Lamps Battery 1 6 624 31 100 1 h 4 LED Ni-Cd 1 6 624 33 200 1 h 4 LED Ni-Cd 1 6 624 34 350 1 h 4 LED Ni-MH 1 6 624 40 100 3 h 4 LED Ni-MH Weatherproof self-contained emergency lighting luminaire LED - B65 LED Weatherproof self-contained emergency lighting luminaire LED - B65 LED n Installation Dimensions (in mm) Surface-mounting 6 614 33 280 59,7 120

RkJQdWJsaXNoZXIy Mzk3OTY=